Mechanical |
Format |
Standard profile PC card |
Connectors |
- ' EXTERNAL I/O' on bracket:
- 26-pin 3-row high-density female sub-D connector
- I/O lines and power output
- 'INTERNAL I/O' on PCB:
- 26-pin 2-row 0.1" pitch IDC female connector
- I/O lines and power output
- 'I/O EXTENSION' on PCB
- 26-pin 2-row 0.05" pitch IDC female connector
- I/O control, data and power
|
LED indicators |
- "ACTIVITY LED's" on bracket
- Two bicolor red and green LED's
- Activity on input and output ports respectively
- "STATUS LED" on PCB
- Bicolor red and green LED's
- Power status
- I/O EXTENSION link status
|
Dimensions |
- PCB L x H: 80 mm x 74 mm , 3.15 in x 2.9 in
- Cable length: 150 mm, 5.9 in
|
General Purpose Inputs and Outputs |
Number of lines |
Configurable mix of 4 types of I/O ports
- Up to 20 TTL inputs
- Up to 20 5V CMOS outputs
- Up to 10 RS-422 inputs
- Up to 10 RS-422 outputs
|
Usage |
- Any I/O input lines can be used by any LIN tool of the I/O Toolbox
- Selected pairs of I/O input lines can be used by any QDC tool of the I/O toolbox to decode A/B signals of a motion encoder
|
Electrical specifications |
- TTL inputs: High-speed 5V-compliant TTL inputs compatible with totem-pole LVTTL, TTL, 5V CMOS drivers
- 5V CMOS outputs: High-speed 5 V CMOS outputs compatible with 5V CMOS and 5V TTL receivers
- RS-422 inputs: High-speed differential inputs compatible with ANSI/EIA/TIA-422 differential line drivers
- RS-422 outputs: High-speed differential inputs compatible with ANSI/EIA/TIA-422 differential line receivers
|
Power output |
Non-isolated, +12V, 1A delivered by the Coaxlink card though the I/O EXTENSION cable |
Electrical |
Supply voltage |
12 V DC delivered by the Coaxlink card through the I/O EXTENSION cable |
Power consumption |
Max. 5 W (excluding 12 V POWER output) |
Environmental conditions |
Operating ambient air temperature |
0 °C to +55 °C / +32 °F to +131 °F |
Operating ambient air humidity |
10% to 90% RH non-condensing |
Storage ambient air temperature |
-20 °C to +70 °C/ -4 °F to +158 °F |
Storage ambient air humidity |
10% to 90% RH non-condensing |
Certifications |
EMC - Immunity |
- EN 55024:2010 / CISPR 24:2010
- EN 55035:2017 / CISPR 35:2016
- EN 61000-4-2:2009
- EN 61000-4-3:2006
- EN 61000-4-4:2004
- EN 61000-4-6:2014
|
KC Certification |
Korean Radio Waves Act, Article 58-2, Clause 3 |
RoHS |
European Union Directive 2015/863 (ROHS3) |
REACH |
European Union Regulation 1907/2006 |
WEEE |
Must be disposed of separately from normal household waste and must be recycled according to local regulations |
Ordering Information |
Product code - Description |
|