HD26F I/O Extension Module - Standard I/O Set

汎用I/O拡張機能モジュール

概要
  • 10本の汎用I/Oラインからなる2番目の標準I/Oセットを提供するモジュール
  • 最初の標準I/OセットにはHD26Fコネクタも提供
  • Coaxlink Octo、Coaxlink Mono CXP-12、Coaxlink Duo CXP-12に対応



比較 販売店


Mechanical
Format Standard profile PC card
Connectors
  • ' EXTERNAL I/O 1' on bracket:
    • 26-pin 3-row high-density female sub-D connector
    • standard I/O lines set #1 and power output
  • ' EXTERNAL I/O 2' on bracket:
    • 26-pin 3-row high-density female sub-D connector
    • standard I/O lines set #2 and power output
  • 'INTERNAL I/O 2 ' on PCB:
    • 26-pin 2-row 0.1" pitch IDC female connector
    • standard I/O lines set #2
  • 'INTERNAL I/O 1' on PCB:
    • 26-pin right-angled 2-row 0.1" pitch IDC female connector
    • connected via the provided INTERNAL I/O cable to the INTERNAL I/O 1 connector of the 3602 Coaxlink Octo card
  • 'I/O EXTENSION' on PCB
    • 26-pin 2-row 0.05" pitch IDC female connector
    • connected via the provided EXTEBSION I/O cable to the EXTENSION I/O connector of the 3602 Coaxlink Octo card
Dimensions
  • PCB L x H: 80 mm x 61.5 mm , 3.15 in x 2.4 in
  • I/O Extension cable length: 150 mm, 5.9 in
  • Internal I/O cable length: 160 mm, 6.3 in
General Purpose Inputs and Outputs
Number of lines 20 I/O lines:
  • 4 differential inputs (DIN)
  • 4 singled-ended TTL inputs/outputs (TTLIO)
  • 8 isolated inputs (IIN)
  • 4 isolated outputs (IOUT)
Usage
  • Any I/O input lines can be used by any LIN tool of the I/O Toolbox
  • Selected pairs of I/O input lines can be used by any QDC tool of the I/O toolbox to decode A/B signals of a motion encoder
Electrical specifications
  • DIN: High-speed differential inputs, up to 5 MHz, compatible with ANSI/EIA/TIA-422/485 differential line drivers and complementary TTL drivers
  • TTLIO: High-speed 5V-compliant TTL inputs or LVTTL outputs, compatible with totem-pole LVTTL, TTL, 5V CMOS drivers or LVTTL, TTL, 3V CMOS receivers
  • IIN: Isolated current-sense inputs with wide voltage input range up to 30V, compatible with totem-pole LVTTL, TTL, 5V CMOS drivers, RS-422 differential line drivers, potential free contacts, solid-state relays and opto-couplers
  • IOUT: Isolated contact outputs compatible with 30V / 100mA loads
NOTE: IIN and IOUT lines provide a functional isolation grade for the circuit technical protection. It does not provide an isolation that can protect a human being from electrical shock!
Power output Non-isolated, +12V, 1A delivered by the Coaxlink card though the I/O EXTENSION cable
Electrical
Supply voltage 3.3 V DC delivered by the Coaxlink card through the I/O EXTENSION cable
Power consumption Max. 3 W (excluding 12 V POWER output)
Environmental conditions
Operating ambient air temperature 0 to +55 °C / +32 to +131 °F
Operating ambient air humidity 10 to 90% RH non-condensing
Storage ambient air temperature -20 to +70 °C/ -4 to +158 °F
Storage ambient air humidity 10% to 90% RH non-condensing
Certifications
EMC - Immunity
  • EN 55035:2017 / CISPR 35:2016
  • EN 61000-6-2:2005 / IEC 61000-6-2:2016
  • EN 61000-4-2:2009
  • EN 61000-4-3:2006
  • EN 61000-4-4:2004
  • EN 61000-4-6:2014
KC Certification Korean Radio Waves Act, Article 58-2, Clause 3
RoHS European Union Directive 2015/863 (ROHS3)
REACH European Union Regulation 1907/2006
WEEE Must be disposed of separately from normal household waste and must be recycled according to local regulations
Ordering Information
Product code - Description