HD26F I/O Extension Module - Fast I/O

General purpose I/O extension module

Module providing a second standard I/O set of 10 general purpose I/O lines
New version with fast 400 kHz isolated current-sense inputs
Also provides a HD26F connector for the first standard I/O set
Compatible with Coaxlink Octo, Coaxlink Mono CXP-12 and Coaxlink Duo CXP-12

Specifications

Mechanical

Format

Standard profile PC card

Connectors

' EXTERNAL I/O 1' on bracket:

26-pin 3-row high-density female sub-D connector

standard I/O lines set #1 and power output

' EXTERNAL I/O 2' on bracket:

26-pin 3-row high-density female sub-D connector

standard I/O lines set #2 and power output

'INTERNAL I/O 2 ' on PCB:

26-pin 2-row 0.1" pitch IDC female connector

standard I/O lines set #2

'INTERNAL I/O 1' on PCB:

26-pin right-angled 2-row 0.1" pitch IDC female connector

connected via the provided INTERNAL I/O cable to the INTERNAL I/O 1 connector of the 3602 Coaxlink Octo card

'I/O EXTENSION' on PCB

26-pin 2-row 0.05" pitch IDC female connector

connected via the provided EXTEBSION I/O cable to the EXTENSION I/O connector of the 3602 Coaxlink Octo card

Dimensions

PCB L x H: 80 mm x 61.5 mm , 3.15 in x 2.4 in

I/O Extension cable length: 150 mm, 5.9 in

Internal I/O cable length: 160 mm, 6.3 in

Weight

Net weight: 100 g [3.5 oz]

Gross weight: 200 g [7.1 oz]

General Purpose Inputs and Outputs

Power output

Non-isolated, +12V, 1A delivered by the Coaxlink card though the I/O EXTENSION cable

Number of lines

20 I/O lines:

4 differential inputs (DIN)

4 singled-ended TTL inputs/outputs (TTLIO)

8 isolated inputs (IIN)

4 isolated outputs (IOUT)

Usage

Any I/O input lines can be used by any LIN tool of the I/O Toolbox

Selected pairs of I/O input lines can be used by any QDC tool of the I/O toolbox to decode A/B signals of a motion encoder

Electrical specifications

DIN: High-speed differential inputs, up to 5 MHz, compatible with ANSI/EIA/TIA-422/485 differential line drivers and complementary TTL drivers

TTLIO: High-speed 5V-compliant TTL inputs or LVTTL outputs, compatible with totem-pole LVTTL, TTL, 5V CMOS drivers or LVTTL, TTL, 3V CMOS receivers

IIN: Isolated current-sense inputs with wide voltage input range up to 30V, compatible with totem-pole LVTTL, TTL, 5V CMOS drivers, RS-422 differential line drivers, potential free contacts, solid-state relays and opto-couplers

IOUT: Isolated contact outputs compatible with 30V / 100mA loads

NOTE: IIN and IOUT lines provide a functional isolation grade for the circuit technical protection. It does not provide an isolation that can protect a human being from electrical shock!

Environmental conditions

Operating ambient air temperature

0 °C to +55 °C / +32 °F to +131 °F

Operating ambient air humidity

10% to 90% RH non-condensing

Storage ambient air temperature

-20 °C to +70 °C/ -4 °F to +158 °F

Storage ambient air humidity

10% to 90% RH non-condensing

Certifications

KC Certification

Korean Radio Waves Act, Article 58-2, Clause 3

RoHS

European Union Directive 2015/863 (ROHS3)

REACH

European Union Regulation 1907/2006

WEEE

Must be disposed of separately from normal household waste and must be recycled according to local regulations

EMC - Immunity

EN 55035:2017 / CISPR 35:2016

EN 61000-6-2:2005 / IEC 61000-6-2:2016

EN 61000-4-2:2009

EN 61000-4-3:2006

EN 61000-4-4:2004

EN 61000-4-6:2014

Electrical

Supply voltage

3.3 V DC delivered by the Coaxlink card through the I/O EXTENSION cable

Power consumption

Max. 3 W (excluding 12 V POWER output)

Ordering Information

Product code - Description

3618 HD26F I/O Extension Module - Fast I/O

Contact our experts

We provide solutions and advice for all industry business.

Contact us