HD26F I/O Extension Module - Fast I/O
General purpose I/O extension module
Specifications
Mechanical
- Format
Standard profile PC card
- Connectors
' EXTERNAL I/O 1' on bracket:
26-pin 3-row high-density female sub-D connector
standard I/O lines set #1 and power output
' EXTERNAL I/O 2' on bracket:
26-pin 3-row high-density female sub-D connector
standard I/O lines set #2 and power output
'INTERNAL I/O 2 ' on PCB:
26-pin 2-row 0.1" pitch IDC female connector
standard I/O lines set #2
'INTERNAL I/O 1' on PCB:
26-pin right-angled 2-row 0.1" pitch IDC female connector
connected via the provided INTERNAL I/O cable to the INTERNAL I/O 1 connector of the 3602 Coaxlink Octo card
'I/O EXTENSION' on PCB
26-pin 2-row 0.05" pitch IDC female connector
connected via the provided EXTEBSION I/O cable to the EXTENSION I/O connector of the 3602 Coaxlink Octo card
- Dimensions
PCB L x H: 80 mm x 61.5 mm , 3.15 in x 2.4 in
I/O Extension cable length: 150 mm, 5.9 in
Internal I/O cable length: 160 mm, 6.3 in
- Weight
Net weight: 100 g [3.5 oz]
Gross weight: 200 g [7.1 oz]
General Purpose Inputs and Outputs
- Power output
Non-isolated, +12V, 1A delivered by the Coaxlink card though the I/O EXTENSION cable
- Number of lines
20 I/O lines:
4 differential inputs (DIN)
4 singled-ended TTL inputs/outputs (TTLIO)
8 isolated inputs (IIN)
4 isolated outputs (IOUT)
- Usage
Any I/O input lines can be used by any LIN tool of the I/O Toolbox
Selected pairs of I/O input lines can be used by any QDC tool of the I/O toolbox to decode A/B signals of a motion encoder
- Electrical specifications
DIN: High-speed differential inputs, up to 5 MHz, compatible with ANSI/EIA/TIA-422/485 differential line drivers and complementary TTL drivers
TTLIO: High-speed 5V-compliant TTL inputs or LVTTL outputs, compatible with totem-pole LVTTL, TTL, 5V CMOS drivers or LVTTL, TTL, 3V CMOS receivers
IIN: Isolated current-sense inputs with wide voltage input range up to 30V, compatible with totem-pole LVTTL, TTL, 5V CMOS drivers, RS-422 differential line drivers, potential free contacts, solid-state relays and opto-couplers
IOUT: Isolated contact outputs compatible with 30V / 100mA loads
NOTE: IIN and IOUT lines provide a functional isolation grade for the circuit technical protection. It does not provide an isolation that can protect a human being from electrical shock!
Environmental conditions
- Operating ambient air temperature
0 °C to +55 °C / +32 °F to +131 °F
- Operating ambient air humidity
10% to 90% RH non-condensing
- Storage ambient air temperature
-20 °C to +70 °C/ -4 °F to +158 °F
- Storage ambient air humidity
10% to 90% RH non-condensing
Certifications
- KC Certification
Korean Radio Waves Act, Article 58-2, Clause 3
- RoHS
European Union Directive 2015/863 (ROHS3)
- REACH
European Union Regulation 1907/2006
- WEEE
Must be disposed of separately from normal household waste and must be recycled according to local regulations
- EMC - Immunity
EN 55035:2017 / CISPR 35:2016
EN 61000-6-2:2005 / IEC 61000-6-2:2016
EN 61000-4-2:2009
EN 61000-4-3:2006
EN 61000-4-4:2004
EN 61000-4-6:2014
Electrical
- Supply voltage
3.3 V DC delivered by the Coaxlink card through the I/O EXTENSION cable
- Power consumption
Max. 3 W (excluding 12 V POWER output)
Ordering Information
- Product code - Description
3618 HD26F I/O Extension Module - Fast I/O