Mechanical |
Format |
Standard profile, half length, 1-lane PCI Express card |
Cooling method |
Air-cooling, fanless |
Mounting |
For insertion in a standard height, 1-lane or higher, PCI Express card slot |
Connectors |
- 'CAMERA LINK' on bracket:
- 26-position Mini Delta Ribbon (MDR) socket
- Camera Link connector
- 'SYSTEM' on bracket:
- 26-pin 3-row high-density male sub-D connector
- I/O lines and power output
- 'SYSTEM' on PCB:
- 26-pin 2-row 0.1" pitch pin header with shrouding
- I/O lines and power output
- 'CAMERA POWER INPUT' on module:
- 4-pin MOLEX power socket
- 12 VDC power input for PoCL camera
|
Dimensions |
PCB L x H: 168 mm x 111 mm, 6.61 in x 4.37 in |
Host bus |
Standard |
PCI Express 1.0 |
Link width |
1 lane |
Link speed |
2.5 GT/s (PCIe 1.0) |
DMA |
32-bit |
Peak delivery bandwidth |
256 MB/s |
Effective (sustained) delivery bandwidth |
180 MB/s (Host PC motherboard dependent) |
Power consumption |
Max. 5.35 W (500 mA @ +3.3V, 300 mA @ +12V), excluding I/O power output |
Camera / video inputs |
Interface standard(s) |
Camera Link |
Connectors |
One Mini Delta Ribbon (MDR) Camera Link (CL) |
Number of cameras |
One Base camera |
Maximum aggregated camera data transfer rate |
2.04 Gbit/s (255 MB/s) |
Camera Link configuration |
Base |
Camera Link clock frequency |
From 20 MHz up to 85 MHz
|
PoCL (Power over Camera Link) |
One PoCL SafePower compliant controller with overload, over-voltage and short-circuit protection |
Camera types |
Grayscale and color (RGB and Bayer) area- and line-scan cameras |
Video delivery |
Raw video format(s) |
- Monochrome formats: Y8, Y10, Y12, Y14, Y16
- Packed RGB color formats: RGB24, RGB32
- Planar RGB color formats: RGB24PL, RGB30PL, RGB36PL, RGB42PL, RGB48PL
- Additional formats: BAYER8, BAYER10, BAYER12, BAYER14, BAYER16, RAW8, RAW10, RAW12, RAW14, RAW16
|
On-board processing |
On-board memory |
32 MB (16 MB for image data) |
Image data stream processing |
- Unpacking of 10-/12-/14-bit to 16-bit with selectable justification to LSb or MSb
|
General Purpose Inputs and Outputs |
Number of lines |
9 I/O lines:
- 4 TTL input/output lines (ENHANCED I/O)
- 2 differential inputs (TRA1, TRA2)
- 1 isolated output (STA)
- 2 multimode input/output lines (ISOA1, ISOA2)
|
Usage |
- Camera and image acquisition trigger
- Light strobe trigger
- Camera synchronization using motion encoder
- General purpose IO
|
Electrical specifications |
- ISOA1, ISOA2: Inputs or outputs, isolated up to 500 V:
- Input: compatible with TTL or 12V signals
- Output: TTL, open-collector or open-emitter
- TRA1, TRA2: Inputs compatible with TTL, LVTTL, differential LVDS, differential RS-422, differential RS-485 signals, protected against electrostatic discharge, with choke for the rejection of common-mode noise
- STA: Opto-isolated outputs, compatible with signals up to 60V, with 3 µs fall time, isolated up to 500V
- ENHANCED IO Inputs or outputs compatible with TTL signals, protected against electrostatic discharge, with high-frequency noise filter
|
Filter control |
- Glitch removal filter available on input lines used as trigger sources:
- Configurable with five time constants:
- 100 ns, 500 ns and 2.5 µs for trigger/ page trigger /page end trigger sources
- 100 ns, 500 ns, 2.5 µs for line trigger source
|
Power output |
- Non-isolated +5V, 1A and +12V, 500 mA with self-resettable fuse protection
- Isolated +5V 250 mA with electronic fuse protection
|
Software |
Host PC Operating System |
- Microsoft Windows 10, 8.1, 7 for x86 (32-bit) and x86-64 (64-bit) processor architectures
- Linux for x86 (32-bit) and x86-64 (64-bit) processor architectures
Refer to release notes for details
|
APIs |
- MultiCam 32- and 64-bit binary libraries (Windows and Linux), for ISO-compliant C/C++ compilers
|
Environmental conditions |
Operating ambient air temperature |
0 °C to +50 °C / +32 °F to +122 °F |
Operating ambient air humidity |
10% to 90% RH non-condensing |
Storage ambient air temperature |
-20 °C to +70 °C/ -4 °F to +158 °F |
Storage ambient air humidity |
10% to 90% RH non-condensing |
Certifications |
Electromagnetic - EMC standards |
- European Council EMC Directive 2004/108/EC
- United States FCC rule 47 CFR 15
|
EMC - Emission |
- EN 55022:2010 Class B
- FCC 47 Part 15 Class B
|
EMC - Immunity |
- EN 55024:2010 Class B
- EN 61000-4-2
- EN 61000-4-3
- EN 61000-4-4
- EN 61000-4-6
|
Flammability |
PCB compliant with UL 94 V-0 |
RoHS |
European Union Directive 2015/863 (ROHS3) |
REACH |
European Union Regulation 1907/2006 |
WEEE |
Must be disposed of separately from normal household waste and must be recycled according to local regulations |
Ordering Information |
Product code - Description |
|